Abstract

Stress state of soft soil foundation under vacuum preloading is completely different from its counterpart under surcharge preloading, and the method of calculating the final settlement of soil mass by means of surcharge preloading (positive pressure) is unreasonable in present design. According to a case of soft foundation stabilized with vacuum preloading and through consolidated-undrained triaxial (CU) test on the specimens sampled in situ, the stress paths under different confining pressure are obtained. The settlement of soft foundation treated with vacuum preloading is calculated by strain isoline method. Compared with the practically measured field data, the errors are analyzed and discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.