Abstract

The single-phase rectifier in traction drive system has the problem of secondary voltage ripple at the dc side, while the LC passive filter device used at present can effectively suppress the secondary voltage ripple at the dc side, but the required parameters are very large, which greatly reduce the power density of the converter. Therefore, this paper deeply analyzes the energy flow of traction drive system, deduces the voltage expression of the intermediate dc capacitance, analyzes the influence of the secondary ripple of dc voltage on the current at the rectifier network side according to the working characteristics of the rectifier, and finally researches the active secondary filtering method at the rectifier dc side.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.