Abstract

This article provides an industrial application method for monitoring and regulating the secondary air through the burner nozzle of a tangentially fired boiler. A geometric model from the inlet of the damper to the burner nozzle was established, which divides the grid for numerical calculation of the flow field to get the drag coefficients of the nozzle and damper under different opening ratios of the damper. In the range of 20–70% opening, the damper has perfect regulation performance, which has the main resistance comparing with that of nozzle. The disc-type damper has a slightly larger resistance than that of the splayed one. A precise corresponding function relationship between the opening ratio and the gas flow rate was established, and base on which, an exact control method on the secondary air damper was proposed. The result can apply to the intelligent transformation of thermal power plants to save energy and reduce consumption.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.