Abstract

An essential issue of the high-frequency isolated converter interconnecting the AC/DC hybrid microgrid is the magnetic flux bias, which will cause saturation of magnetic core if not controlled appropriately. In order to solve the problem, this paper analyzes the reasons of the flux bias and models the magnetizing current in the s-domain. Based on the analysis and the model, a strategy for magnetic flux bias reduction is proposed. The strategy compares the peak of the magnetizing current at each switching time and controls the average of the magnetizing current to zero by applying an additional voltage to the winding of the transformer at the DC side. The simulation base on PSIM platform is implemented and the results verify the validity of the proposed strategy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.