Abstract

Objective: To conduct quantitative evaluation on the revise requirements of Specifications of Air Sampling for Hazardous Substances Monitoring in the Workplace (GBZ 159-2004) , clarify the problems and suggestions during its implementation for improvement, and provide a basis for the revision of the standard. Methods: From April to September 2021, stratified convenient sampling method was adopted and semi-open questionnaire was used to investigate the occupational health personnel in CDC, occupational prevention and control institutes, employers, third-party technical service institutions and universitie. The entropy weight of each index and the score based on entropy weight of GBZ 159 were calculated. Spearman rank correlation analysis was used to describe the correlation between the two indexes and radar chart was drawn for comprehensive evaluation. Results: A total of 151 questionnaires were received from the respondents, of which 147 were valid, with an effective recovery rate of 97.35%, involving 29 provinces, autonomous regions and municipalities. The median G scores of the necessity and urgency of GBZ 159 revision based on entropy weight were 2.84 and 3.17, respectively, and the difference was statistically significant (M=-25.50, P<0.001) . The trend of the score G of necessity and urgency based on entropy weight was basically the same for all secondary items (r(s)=0.9998, P<0.001) , and the score G of urgency based on entropy weight was higher than that of necessity. The highest score G of necessity and urgency based on entropy weight was "3.13 long time sampling", which were 7.56 and 8.23 respectively. This was followed by "3.12 short time sampling", which were 7.19 and 7.13 respectively. Conclusion: GBZ 159 has encountered some new problems and challenges in the implementation process, and some of its technical indicators have been out of line with the actual practice of occupational health at present. These are the two items that urgently needs to be revised and improved, such as "3.13 long time sampling" and "3.12 short time sampling" and other items need to be revised and improved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.