Abstract

To achieve sufficient air conditioning of large buildings, reasonable air distribution in indoor spaces is an effective method for creating stratified air conditioning. Therefore, optimizing the air distribution in large buildings is extremely significant. In this paper, we expound on a new method for air distribution design and optimization based on target value evaluation and summarize the relevant design processes based on an orthogonal test and by decoupling the effects of the size of the tuyere, airflow temperature, air-supply angle and velocity on air distribution. Then, we present a design case. To optimize the distribution of a lateral air supply in winter, the deflection angle, velocity and temperature of the air supply can be determined in turn. For the large and tall building types addressed in this paper, the optimal air-supply angle is 2°, the optimal air-supply velocity is 8 m/s, and the optimal air-supply temperature is 19 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.