In order to get a solution for inspecting the pre-tightening state of pre-stressed frame heavy hydraulic press,the change law of the tension force in the tie rod with the pulling force at the end of the tie rod,which shows that the tension force curve is nearly a two-segment broken line with a curved transition caused by the insufficient connection stiffness of nut,is obtained by mechanics analysis.A measurement principle for obtaining the pre-tightening force of the tie rod without release of the tightening of tie rod is presented and the insensitivity of measurement precision to the stick-on orientation of the strain gauge is theoretically proved.A measurement system is developed on the virtual instrument platform,LabVIEW,of NI Company.Experiments are carried out to verify the correctness of the principle and the feasibility of the system by using a physical model.The research provides an implementation means for evaluating the pre-stress status of the pre-tightening state of heavy hydraulic press in service,as well as the necessary condition for malfunction diagnosis of the integrity of heavy hydraulic press.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.