Abstract

Iron-carbon micro-electrolysis was applied in the treatment of the electroplating wastewater containing copper, and the parameters that affected the efficiencies of the wastewater treatment had been discussed, The results indicated that the optimal experimental conditions were initial pH 4, stirring speed 100r/min, total mass of iron and carbon 4g/0.1L, iron carbon mass ratio of 1, reaction time was 40min. The removal rate of the Cu2+was 99% or more, the effluent can meet emissions standards

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.