Abstract

A way of measuring the average cross-sectional void fraction for vertically rising oil pipes by using closing valves quickly and optical fiber probe has been researched. Experiments were performed in oil-gas two-phase flow and the range of the average void fraction is 0.1~0.5. The relationship between average cross-sectional void fraction of a oil-gas two-phase flow and pipe’s center void fraction in vertically rising oil pipes, for different pipe diameters and varying oil flow, is obtained. An exponential model of average void fraction is also obtained with reference to Bankoff’s[1] variable density model. It is found that local void fraction reduces from center in radial direction and the local void fraction maximum value appears in the pipe’s center.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.