Abstract

Vibration appears in the main drive system of the six-roller cold rolling mill of one plant. The oscillation frequency is 2.5 Hz. The oscillation cycle is 0.4 second. The oscillation period has nothing to do with the speed. Using the finite element software ANSYS, the low natural frequency is got through the modal analysis and harmonic response analysis based on the measured vibration data from the field. Horizontal vibration is the main vibration mode and it is the electromechanical coupling vibration. Main motor is controlled by IEGT inverter of TEMIC and the low frequency harmonic component is difficult to eliminate. AC drive trap filter is designed to dodge the 2.5 Hz frequency. The solution has achieved the recognition by the TEMIC company. The problem was solved and good results were obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.