Abstract
The electrical insulation design is important for high-Tc superconducting (HTS) cable because the cable is operated in a medium voltage environment. For the insulation design of HTS cable, it is necessary to investigate the ac, impulse breakdown, and partial discharge inception stress of a liquid nitrogen/polypropylene laminated paper composite insulation system. These results were used to design the electrical insulation of 22.9-kV-class HTS cable in Korea and cable was manufactured. A manufactured mini-model HTS cable was evaluated for ac withstand voltage, impulse withstand voltage, breakdown and dielectric tangent loss (tan/spl delta/). From these tests, the cable has satisfied the standard technical specification of KEPCO in Korea. The breakdown voltage was 110 kV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.