Abstract
Initiating event analysis is an essential prerequisite of conducting probabilistic safety assessment for nuclear reactors, which plays an important role in improving the core design, identifying fault, and guiding operation. In order to determine the initiating event list of SIMONS (Small Innovative helium-xenon cooled Mobile Nuclear power System), preliminary researches on the initial event of SIMONS were carried out using the MLD (Main Logic Diagram) analysis method and referring to the initial event list and initial event analysis theory of other nuclear reactors such as HTGR (High Temperature Gas-cooled Reactor), MSR (Molten Salt Reactor), and PWR (Pressurized water reactor). With employing these methods, a total of 31 initial events are identified for SIMONS based on its latest conceptual design. These initial events are then divided into six groups according to the accident types, which are core heat removal increase, core heat removal decrease, abnormal reactivity and power distribution, pipeline crevasse and equipment leakage, anticipated transients without scram, and disasters (internal and external). The obtained results can provide a theoretical basis for the further safety analysis of SIMONS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.