Abstract

In order to solve the problem that the magnetic coupling resonant WPT system with SS compensation structure causes a decrease in transmission efficiency when it is detuned, the resonant state of the system is tracked by detecting the output voltage of the transmitting coil inverter and the coil current of the receiving coil. Phase difference is converted into dc voltage signal with phase discriminator, ADC module is used to sample dc signal, PID algorithm is used to track resonance frequency of the system, 90° phase difference is taken as expected value of PID algorithm, and 90° phase shift is indirectly realized by digital method. The experiment shows that the resonant frequency tracking method is effective.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.