Abstract
Maldistribution of gas-solid tow-phase flow field in circulating fluidized bed (CFB) can cause a series of problems, such as thermal deviation, wear of water walls, etc. In this study, a cold model CFB facility, which was scaled down from a commercial 300MWe CFB boiler with three cyclones placed in an array, was built up and a series of experiments were conducted the flow non-uniformity. The results showed that in CFB boiler with multiple cyclones, the distribution of bed material in the circulation loops is different and uncertain. The gas-solid two-phase flow in the furnace is unbiased, even the circulating rates in the circulation loops are different. The circulating rate in the middle loop is larger than that in the side loops. The difference is less than 10%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.