Abstract

As a clean energy source, nuclear power has broad prospects for development. It is of great significance to study the seismic response of nuclear power plants. PLAXIS software is used to establish the whole finite element model of AP1000 nuclear power plant shielding plant structure. Considering the foundation embedding and soil-structure interaction, the seismic response analysis of nuclear power plants on different inclined soft rock sites was carried out under seismic loading. By analyzing and comparing the calculated results of the floor response spectrum amplification factor, the peak frequency of the floor response spectrum at the important position is smaller than the peak frequency of the design response spectrum, the inclination of the inclined site will affect the peak frequency and cause the amplification effect.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call