Abstract
Abstract To verify the failure rate of intelligent energy meter in charging pile and whether it can meet the reliability requirements in “general technical specification for single-phase intelligent electric energy meter (2020)”. Take 20 smart meter samples from four manufacturers, use the accelerated life model and carry out the accelerated test in the way of stress acceleration for a total of 4000 hours, and evaluate the failure rate indicators under normal working stress. The test results show that the single-phase intelligent watt hour meters produced by the four manufacturers can meet the reliability requirements such as annual failure rate index. The accelerated test theory is applied to the reliability life and failure rate evaluation of intelligent electric energy meter to shorten the test time, improve the test efficiency and reduce the test cost.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.