Abstract
A calculation method for double-stream counter-current coil-wound heat exchanger is presented for methanol-methanol heat exchange process. The numerical simulation method is applied to determine the basic physical parameters of double-stream spiral pipes. A recycling methanol cooler is designed and calculated by numerical simulation and programmed iterative calculation. The calculation data is analyzed by comparing with different variables. The result shows that the introduction of numerical simulation can simplify the pipe winding process and accelerate the calculation and design of overall configuration. This method can be used for physical modeling and heat transfer calculating of spiral pipes in double-stream coil wound heat exchanger, program to calculate the complex heat transfer changing with different variables and optimize the overall design and calculation process of double-stream spiral pipe bundles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.