Abstract

With the purpose of the design problem of electromagnetic launch distributed measurement and control system, this paper proposes a design method of scalable large-scale distributed interconnected measurement and control system based on FlexRay bus. The task execution time deviation of each node in the distributed system, including phase deviation and frequency deviation, is reduced by using the macro tick generation process and clock synchronization process to achieve task synchronization in the distributed system. The synchronization of timing generation is realized based on the universal clock technology. When the timing interval is zero, the pulse power units are guaranteed to be close to the ideal full synchronization, thus ensuring that the released energy during transmission is close to the design value. In the state of adjustable timing, when the pulse power supply module conducts pulse discharge, the trigger discharge times of the modules are set according to the load needs. The flat top, sawtooth, and other characteristic current waveforms are adjusted accurately. At the same time, a combined multi-level protection structure based on hardware and software is realized. The verification results show that the distributed electromagnetic launch measurement and control system implemented in this paper can meet the high efficiency, fast and continuous launch target.