Abstract

The centrifugal pump's performance curves are the most important chart to reveal relevance of different performance parameters. They can show pump's function comprehensively and graphically. However these curves can't be predicted and designed precisely, duo to the complicated flow inside the impeller and the incomplete way to design pump. The complete shape of performance curves can be gained only after test. With the development of industry, many applications need the pump operating well at different flow conditions. It means the pump's performance curves should pass some specific points. This is a problem to the designer who still uses the traditional way to design pumps. In this paper, the Design of experiments was applied to arrange a plan of experiments. Because the theory equations of performance curves contain many geometry factors of impeller, changing these factors have different influence on the shape of curves, the relationship between geometry factors and the performance under different operation points been attained after using variance analysis to deal with experiment data. The relevant regression models and graphs were drawn to help understand these relationships. Depending on the predicted values of geometry factors pump's impeller was redesigned, and the pump's performance been simulated for saving time and cost. Test shows that the shape of performance curves satisfy design objective, this example can be taken as a reference of pump's specific designs.