For the continuously-varying dynamic pressure flutter test data in the high-speed wind tunnel; this paper analyzes the strengths and weaknesses of the data Processing Method in this field. The data selection and stacking mode is improved. A Butterworth IIR digital filter is used for digital filtering. The power spectral density function is computed by Fourier transform of the autocorrelation function. A pick-hold method is used to predict the flutter critical point. It is indicated that our method features high accuracy and efficiency by theoretical analysis and wind tunnel flutter test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.