Abstract

In order to reduce the vibration and noise of permanent magnet synchronous motors, this paper proposes a control strategy by analyzing the relationship between the vibration and noise of the permanent magnet synchronous motor and the current harmonics of the inverter based on actual project applications. Some methods include random switching frequency modulation technology, random pulse position modulation technology and dead zone compensation technology on current harmonics are analyzed respectively in this paper. Then this paper proposed a mixed control strategy, which combined with random switching frequency-random and pulse position-dead zone compensation methods. Matlab tools are used to simulation and verification the Mixed control strategy. Simulation and experimental results show that this control strategy can effectively reduce the total underwater noise level of permanent magnet synchronous motors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.