Abstract

The traditional LCL-filter third-order system grid-connected inverter may cause the resonance phenomenon without damping. Also, it will be affected by the distorted grid-voltage background harmonics. In order to overcome these problems, based on the passive damping method, a new control strategy is proposed. The paper analyses the current waveform performance of grid-connected inverter in the condition of grid-voltage background harmonics, derives the feed-forward function for grid-connected inverter. The disadvantages of passive damping could be well solved by damping resistor virtualization of the original system, which realized the active damping suppression of resonance. Simulation results based on the Heric single-phase transformerless grid-connected inverter verify the correctness of the 2éQ: theoretical analysis"theoretical analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.