Abstract
Motor hangers are key components of high-speed trains. Local cracking of motor hangers in service is investigated in this study by employing fracture analysis, on-track tests, finite element analysis, etc., to determine the cause of failure. Macro- and microfracture analyses show that cracks originate from weld defects and propagate to the external surface of the lower cover plate. Time domain, frequency domain, and time-frequency domain analyses indicate that both of the dominant frequencies of the stress and the vibration acceleration are 100 Hz, which are consistent with the pulsating torque frequency. The pulsating torque of the motor induced by the current fluctuation excites the resonance mode of the motor hanger, which brings out the possibility of fatigue crack initiation and propagation under operating conditions. The results show that welding defects reduce the fatigue strength of the weld, and high-amplitude and high-frequency vibrations caused by the pulsating torque of the motor eventually lead to the failure of the motor hanger. The study provides a reference for the structural design of a bogie drive system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.