Abstract

In order to improve the circuit working efficiency of zero-voltage zero-current transition Boost converter, an improved modulation strategy was proposed. The main switch can only achieve zero-current turn-on under traditional modulation strategy. However, the change to the turn-on time of main switch and the turn-off time of auxiliary switch can make the main switch achieve zero-voltage zero-current turn-on and the auxiliary switch realize zero-voltage zero-current turn-off in advance as well. The simulation results show that the main switch can achieve zero-voltage zero-current turn-on and the auxiliary switch could realize zero- voltage zero-current turn-off, the circuit working efficiency was improved.