Abstract

Large-Fresnel-number unstable-waveguide hybrid resonators employing spherical resonator mirrors suffer from spherical aberration, which adversely affects beam quality and alignment sensitivity. In this paper, we present experimental and numerical wave-optics simulations of the beam characteristics of a negative-branch hybrid resonator having parabolic mirrors with a large equivalent Fresnel number in the unstable direction. These results are compared with a resonator using spherical mirrors. Using parabolic mirrors, the output beam has a smaller beam spot size and higher power density at the focal plane. We found that the power extraction efficiency is 3.5% higher when compared with a resonator using spherical mirrors as the cavity length was varied between -1 and 1 mm from the ideal confocal resonator. In addition, the power extraction efficiency is 5.6% higher for mirror tilt angles varied between -6 and 6 mrad. Furthermore, the output propagating field is similar to a converging wave for a spherical mirror resonator and the output beam direction deviates 3.5 mrad from the optical axis. The simulation results are in good agreement with the experimental results.