Abstract

An efficient implementation of lightweight design is the use of continuous carbon fiber reinforced plastics (CFRP) due to their outstanding specific mechanical properties. Embedded metal elements, so-called inserts, can be used to join metal-based attachments to structural CFRP parts in the context of multi-material design. They differ from other mechanical fasteners and have distinctive benefits. In particular, drilling of the components to be joined can be avoided and, depending on the preforming, fiber continuity can be maintained using such elements. Thus, no local bearing stress is anticipated. Previous work published by the authors [1] dealt with a systematic research of the influence of different types of stresses on the load bearing capacity of welded inserts. This contribution aims at the investigation of the performance of shape-optimized inserts under the same types of loading to compare with the results of the welded inserts serving as a reference. For that purpose, the respective load bearing capacities were evaluated after preinduced damages from impact tests and thermal cycling. In addition, dynamic high-speed tensile tests (pull-out) were conducted under different loading velocities. It is shown that the load bearing capacities increased up to 19% for high velocities (250 mm/s) in comparison to quasi-static loading conditions (1.5 mm/min) showing an obvious strain rate dependency of the CFRP. Quasi-static residual strength measurements under tensile loading identified the influence of the respective preinduced damages of the insert. Influence of the thermal loading condition was evaluated by placing the specimens in a climate chamber and exposing it to various numbers of temperature cycles from-40 °C to +80 °C with a duration time of 1.5 hours each. Here, it turned out that already 10 temperature cycles decreased the quasi-static load bearing capacity up to 31%. According to DIN EN 6038 the specimens were loaded with different impact energies and the residual strength were measured carrying out pull-out tests. It could be shown that the damage tolerance is significantly lower for the shape-optimized insert due to failure-critical delamination. The optimized insert also endured lower impact energies and the influence on the performance was higher.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call