Abstract

The synchronization among the central electrode ignition control system, high-speed schlieren imaging system and pressure data acquisition system inside a constant volume combustion chamber (CVCC) should be accurately controlled in the study of the laminar burning velocity of fuel by spherical expansion flame method in a CVCC. In this paper, the digital delay pulse generator and the high-speed data acquisition card are used to control the synchronization among the abovementioned three systems with the control error in 30 μs, and then the schlieren image of the flame front and the pressure inside a CVCC are captured successfully. These lay a solid foundation for the measurement of laminar burning velocity by constant pressure method (CPM) and constant volume method (CVM).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.