Abstract

The paper presents the results of precast lintels made of AAC with a total length 2.0 m. The study was divided into two series of basic and general. In the basic series, lintel was studied according to the recommendations of codes EN 846-9: 2002 and EN 1356: 1999. In the general series consisting of the 6 models, lintels with an interacting wall of varying heights were examined. During the test, forces, displacements and deformations were measured using inductive transducers forces and displacements. The basic and the general series demonstrated, among other things, that the destruction of the elements followed in the zone of supporting due to shear.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.