Abstract

In a parallelly operated system composed of multi distributed generations (DGs), traditional droop control is usually utilized for load distribution. This article introduces the basic principle which is based on the characteristics of the parallel inverters power droop, and analyzes the circulation phenomenon of parallel inverters in Micro-grids. Due to the influences of feeder impedances and local load, a larger power distribution error may be caused by traditional droop control; a new kind of droop control strategy which was based on virtual impedance was put forward to improve the unequal distribution of power by adjusting the droop parameters. Results of simulation and experiments show that the proposed control strategy is feasible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.