Abstract
Both aerodynamic and aeroacoustic performance of collateral axial flow fan system inside outdoor unit of air-conditioner is investigated by experiment and CFD simulation. Noise spectrum of outdoor unit is composed of broadband and discrete frequency noise. The main contribution of noise is broadband one. The discrete frequency noise is located at blade passing frequency and its harmonics of the upside and downside impeller respectively. Little interaction is found between downside and upside impeller through results of acoustic and flow filed. Vortex sound theory shows that broadband noise of outdoor unit is mainly caused by vortex shedding at trailing edge of impeller and discrete noise is caused by tip vortex. Based on acoustic analogy and CFD simulation, broadband and discrete frequency noise is well predicted with little error to experimental one.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.