Abstract

High-speed EMU temperature sensors are used to detect important parameters such as temperature on the train. The thermal response time of the temperature sensor is the main factor affecting the temperature measurement. The failure of the thermal response time will lead to the failure or false positives of the vehicle temperature sensor, which will cause the speed limit and stop, which will seriously affect the railway operation order. This paper focuses on the thermal response time of the temperature sensor of the high-speed EMU and analyzes the dissection and simulation of the temperature sensor. The results show that the reason for the failure of the thermal response time is that the sensor probe into the air leads to the thermal resistance becomes larger, reduces the heat transfer speed, and finally makes the thermal response time longer. Finally, according to the diagnostic analysis, results put forward the corresponding measures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.