Abstract

The avermectin wastewater was treated with UASB technique. The paper was focused mainly on the removal rate of COD and the change of ammonia nitrogen of influent and effluent wastewater in the first running stage. At the stable phase of anaerobic operation, the removal rate of COD could be stabilized at 85% when the influent volume load was 9.21 kg/(m3•d), and the effluent COD was about 1400 mg/L. As for ammonia nitrogen concentration of influent and effluent wastewater, in the first 50 days, the former was larger than the latter, after then, it was opposite. In the condition of same volume load but different hydraulic retention time (COD concentration of influent being different), COD removal rate kept almost the same. In the second running stage, the influent COD volume load reached 9.21 kg/(m3•d) at the 16th day, with the COD removal rate being around 87%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.