According to the working process of dynamic throttling element flowmeter, the Reynolds number keeps constant when the flow is steady. The way to change the pressure drop is to change the local pressure loss. Based on the Fluent software, analyze how the structure parameters of venturi tube affect pressure drop. With the completion of flowmeter prototype, test the dynamic throttling element by using a kind of binary flow calibration platform. According to the test result, figure out that the optimization can perfectly meet the real flowing condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.