Abstract

The primary aim of this study is to empirically examine the viability of utilizing ice as a cooling agent in order to enhance the air cooling efficiency of a portable cooler through the utilization of latent heat of fusion. A portable air cooler has been constructed using a polyurethane insulation box that is readily accessible in the market. The box has been combined with a galvanized iron conduit, which has a square cross section measuring 3 inches by 3 inches, to facilitate the passage of air. This tunnel effectively isolates the airflow from the ice, while nevertheless facilitating thermal conduction between the ice and the surrounding air. The experimental testing of this system was conducted within a range of ambient temperatures, specifically between 34.6 ℃ and 30 ℃. According to the test results, the system demonstrates the capability to lower the temperature of air by up to 11.4 ℃. The findings also indicate that the cooling efficiency of the system is influenced by fluctuations in air temperature, room temperature, and duration.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.