Abstract
Objective: To assess development of objective, subjective and indirect measures of fatigue during simulated infant cardiopulmonary resuscitation (CPR) with two different methods.Methods: Using a neonatal manikin, 17 subject-pairs were randomized in a crossover design to provide 5-min CPR with a 3:1 chest compression (CC) to ventilation (C:V) ratio and continuous CCs at a rate of 120 min−1 with asynchronous ventilations (CCaV-120). We measured participants’ changes in heart rate (HR) and mean arterial pressure (MAP); perceived level of fatigue on a validated Likert scale; and manikin CC measures.Results: CCaV-120 compared with a 3:1 C:V ratio resulted in a change during 5-min of CPR in HR 49 versus 40 bpm (p = 0.01), and MAP 1.7 versus −2.8 mmHg (p = 0.03); fatigue rated on a Likert scale 12.9 versus 11.4 (p = 0.2); and a significant decay in CC depth after 90 s (p = 0.03).Conclusions: The results indicate a trend toward more fatigue during simulated CPR in CCaV-120 compared to the recommended 3:1 C:V CPR. These results support current guidelines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.