Abstract

Cardiogenic shock has poor prognosis with medical management alone and/or intra-aortic balloon pump support. Levitronix Centrimag®centrifugal pump has been increasingly used to bridge patients to decision for further advanced mechanical uni- or bi-ventricular support with a view to heart transplantation on the newly implemented super-urgent recipient scheme. We sought to review our experience as a designated centre for mechanical circulatory support to investigate its role despite the emergence of percutaneously implantable miniature devices. Between April 2009 and December 2015, 98 patients in cardiogenic shock [age 41.4 ± 12.7 years; 52 (53%) male and 46 (47%) female] underwent mechanical circulatory support of whom 90 were treated with Levitronix Centrimag as a primary procedure. Diagnosis was dilated cardiomyopathy [37 (38.1%)], ischaemic cardiomyopathy [25 (25.8%)], and other [36 (36.1%)]. Main indications were cardiogenic shock or decompensated heart failure. Other indications were early graft failure following heart transplant or right ventricular failure following left ventricular assist device insertion. Levitronix support was as follows: extra corporeal membrane oxygenation [22 (24.4%) central, 26 (28.9%) peripheral], Left Ventricular Assist Device [12 (13.3%)], Right Ventricular Assist Device [5 (5.6%)], and Bi-Ventricular Assist Device [25 (27.8%)]. The average duration of support on Levitronix was 17.1 days (range 1–111). The 30-day survival was 52% (47 patients), 6-month survival was 40% (36 patients), and 12-month survival was 37.7% (34 patients). Of the surviving patients, five underwent successful orthotopic heart transplantation, one received a HeartMate II which was subsequently explanted because of myocardial recovery, and one received a HeartMate II and is currently on the transplant list. Cause of death while on support was multiorgan failure [12 (13.3%)], cardiovascular system (CVA)/Neurological [10 (11.1%)], further haemodynamic deterioration [9 (10%)], graft failure [5 (5.6%)], bleeding [4 (4.4%)], sepsis [3 (3.3%)], myocardial infarction [3 (3.3%)], right ventricular failure [3 (3.3%)], pulmonary embolism [1 (1.1%)], embolic [1 (1.1%)], respiratory failure [1 (1.1%)], influenza + rejection [1 (1.1%)], and unknown [3 (3.3%)]. Levitronix Centrimag® remains a versatile device with potential in an acute setting. Early aggressive treatment and a younger patient population may well justify its use.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.