Abstract

The aim was to study the efficacy of rescue High Frequency Oscillatory Ventilation (HFOV) in improving the oxygenation and ventilation in neonates with acute respiratory failure after failing Conventional Mechanical Ventilation (CMV). Primary outcome was short term oxygenation, lung recruitment, and ventilation and secondary outcome studied was survival. 675 babies were ventilated and 97 of them received HFOV. HFOV significantly improved oxygenation index, alveolar-arterial oxygen gradient, pH, PCO2, PO2 and caused better lung recruitment within 2 hours. Fifty seven babies (58.77%) survived and the mortality was more in <28 weeks, babies with pulmonary hemorrhage, sepsis and CDH.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.