Abstract

The purpose of this study was to assess the reproducibility of substantia nigra pars compacta (SNpc) and locus coeruleus (LC) delineation and measurement with neuromelanin-sensitive MRI. Eleven subjects underwent two neuromelanin-sensitive MRI scans. SNpc and LC volumes were extracted for each scan. Reproducibility of volume and magnetization transfer contrast measurements in SNpc and LC was assessed using intraclass correlation coefficients (ICC) and dice similarity coefficients (DSC). SNpc and LC volume measurements showed excellent reproducibility (SNpc-ICC: 0.94, p<0.001; LC-ICC: 0.96, p<0.001). SNpc and LC were accurately delineated between scans (SNpc-DSC: 0.80±0.03; LC-DSC: 0.63±0.07). Neuromelanin-sensitive MRI can consistently delineate SNpc and LC.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call