Abstract
ObjectivesTo evaluate the reproducibility of complete arch scanning with multiple implant scan bodies using a laboratory scanner. MethodsA master model of edentulous maxillary arch with 6 implants was fabricated. PEEK scan bodies were inserted into the model and consecutively scanned using a dental laboratory scanner (N = 10, Group C). Another 10 scans were performed with each scan body detached and reinserted into the same site between each scan (Group CR). The last group of scanning was performed with the scan bodies detached and randomly repositioned between each scan (N = 10, Group RR). Virtual models were created and the inter-implant distances and angles were measured using an inspection software. Accuracy of the complete arch scans was calculated and compared using Two-Way ANOVA (⍺ = 0.05). ResultsSignificant greater distance distortion was found in CR (27.6 ± 18.9 μm) and RR (34.2 ± 25.0 μm). No significant difference in angular distortion was found among 3 groups. The greatest distance distortion was found in the anterior and cross-arch region of the arch. The smallest angular distortion was found in the first scanned sextant, with increasing distortion along the scanning path of the arch. The distance precision was significantly reduced in group CR and RR, while the angular precision was significantly reduced in group RR only. ConclusionReproducibility of complete arch scanning was significantly affected by repositioning of the scan bodies using a laboratory scanner. Repeated and random repositioning of the scan bodies would decrease the reproducibility of the spatial position and angle of the virtual implant. The distortion appeared to be small and within the clinical tolerance. Clinical significanceHigh-precision transfer of the implant information from intra-oral environment to dental laboratory is a prerequisite for the success of implant-supported prosthesis. Although laboratory scanners seem to be accurate, their accuracy is also affected by the precision and attachment procedure of the implant scan bodies and that has always been overlooked.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.