Abstract

The reproducibility of median-time-to-failure (t 50 ) measurements was determined in an interlaboratory experiment in which 11 laboratories and a reference laboratory took part. Each laboratory used a method of its choosing to test equivalent samples under the same conditions of current density and oven temperature. The between-laboratory reproducibility of t 50 measurements normalized to one metallization temperature was dependent on current-density stress: at 1.0 MA /cm2it was within 15 percent, while at 2.5 MA/cm2it was generally within 50 percent. The primary source for variability is in estimating the temperature rise of the test metallization due to joule heating. Recommendations are given for the design and test of electromigration test structures to improve the reproducibility of t 50 measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.