Abstract

BackgroundIn end-stage renal disease (ESRD) patients, increased arterial stiffness detected by carotid-femoral pulse wave velocity (cf-PWV) is associated with fatal cardiovascular events and all-cause mortality. Since cf-PWV is an operator-dependent technique, poor reproducibility may be a source of bias in the estimation of arterial stiffness.ObjectivesWe assessed the week-to-week reproducibility of cf-PWV and radial artery pulse wave analysis in healthy subjects and ESRD patients. We also determined the extent of patient eligibility, enrollment, acceptance, and comfort.MethodsIn a cohort study design, independent tonometric examinations of carotid, femoral, and radial arteries were conducted in 20 healthy subjects and 15 ESRD patients attending chronic hemodialysis treatments according to a randomized sequence by two operators on 2 days scheduled 1-week apart. cf-PWV, augmentation index (AIx@HR75) and central pulse pressure (CPP) were the outcome measures. Patients were tested at mid-week and prior to dialysis treatment. The variability on the distance measured between the suprasternal notch and femoral site using two different methods (standard vs direct) was compared. A post-examination survey assessed acceptance and comfort associated with examinations. Reproducibility was evaluated by intra-class correlations (ICCs).ResultsThe mean age for healthy subjects and ESRD patients was 45 ± 12 and 63 ± 16 years, respectively. ESRD patients had higher cf-PWV (p = 0.0002), elevated AIx@HR75 (p = 0.003), and increased CPP (p = 0.001) compared to healthy subjects. The mean inter-visit differences for all stiffness indices were non-significant (p > 0.05), but the mean inter-operator differences for the cf-PWV were significant only in the healthy subject group (−0.7 m/s; p = 0.02). The ICCs between operators and visits were higher for the ESRD group compared to the healthy subjects (between operators, 0.870 vs 0.461; between visits, 0.830 vs 0.570). Distances were longer (p < 0.001), but less variable with the standard method compared to the direct method (healthy subjects, p = 0.036; ESRD, p = 0.39). There was a high rate of patient acceptance and minimal discomfort.ConclusionsWeek-to-week measurements of cf-PWV and pulse wave analysis are highly reproducible in ESRD patients prior to hemodialysis treatment. The high reproducibility and minimal test-to-test variations encourage use of cf-PWV to monitor changes in arterial stiffness and the efficacy of interventions in ESRD patients.Trial registrationClinicalTrials.gov, NCT02196610.Electronic supplementary materialThe online version of this article (doi:10.1186/s40697-016-0109-6) contains supplementary material, which is available to authorized users.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.