Abstract

Using data from the Vermont Breast Cancer Surveillance System (VBCSS), we studied the reproducibility of Breast Imaging Reporting and Data System (BI-RADS) breast density among community radiologists interpreting mammograms in a cohort of 11,755 postmenopausal women. Radiologists interpreting two or more film-screen screening or bilateral diagnostic mammograms for the same woman within a 3- to 24-month period during 1996-2006 were eligible. We observed moderate-to-substantial overall intra-rater agreement for use of BI-RADS breast density in clinical practice, with an overall intra-radiologist percent agreement of 77.2% (95% confidence interval (CI), 74.5-79.5%), an overall simple kappa of 0.58 (95% CI, 0.55-0.61), and an overall weighted kappa of 0.70 (95% CI, 0.68-0.73). Agreement exhibited by individual radiologists varied widely, with intra-radiologist percent agreement ranging from 62.1% to 87.4% and simple kappa ranging from 0.19 to 0.69 across individual radiologists. Our findings underscore the need for additional evaluation of the BI-RADS breast density categorization system in clinical practice.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.