A total of 225 pairs of duplicate Gram-stained slides from three hospitals in Jakarta were evaluated independently by a local (University of Indonesia, Jakarta) and a referral (University of Washington, Seattle) laboratory by the new scoring criteria proposed by Nugent et al. The correlation coefficients of the duplicate Gram stain scores ranged from 0.65 to 0.83. The kappa statistics for the bacterial vaginosis category (no, score of 0 to 6; yes, score of 7 to 10) ranged from 0.62 to 0.77. These findings confirm the good to excellent interobserver reliability of the new scoring system and the importance of slide preparation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.