Abstract

Dedicated breast PET (dbPET) systems have improved the detection of small breast cancers but have increased false-positive diagnoses due to an increased chance of noise detection. This study examined whether reproducibility assessment using paired images helped to improve noise discrimination and diagnostic performance in dbPET. This study included 21 patients with newly diagnosed breast cancer who underwent [18F]FDG-dbPET and contrast-enhanced breast MRI. A 10-min dbPET data scan was acquired per breast, and two sets of reconstructed images were generated (named dbPET-1 and dbPET-2, respectively), each of which consisted of randomly allocated 5-min data from the 10-min data. Uptake spots higher than the background were indexed for the study with visual assessment. All indexed uptakes on dbPET-1 were evaluated using dbPET-2 for reproducibility. MRI findings based on the Breast Imaging-Reporting and Data System (BI-RADS) 2013 were used as the gold standard. Uptake spots that corresponded to BI-RADS 1 on MRI were considered noise, while those with BI-RADS 4b-6 were considered malignancies. The diagnostic performance of dbPET for malignancy was evaluated using four different criteria: any uptake on dbPET-1 regarded as positive (criterion A), a subjective visual assessment of dbPET-1 (criterion B), reproducibility assessment between dbPET-1 and dbPET-2 (criterion C), and a combination of B and C (criterion D). A total of 213 indexed uptake spots were identified on dbPET-1, including 152, 15, 6, 6, and 34 lesions classified as BI-RADS MRI categories 1, 2, 4b, 4c, and 5, respectively. Overall, 31.9% of the index uptake values were reproducible. All malignant lesions were reproducible, whereas 93.4% of noise was not reproducible. The sensitivities for malignancy for criteria A, B, C, and D were 100%, 91.3%, 100%, and 91.3%, respectively, with positive predictive values (PPVs) of 21.4%, 68.9%, 67.6%, and 82.4%, respectively. Our results demonstrated that reproducibility assessment helped reduce false-positive findings caused by noise on dbPET without lowering the sensitivity for malignancy. While subjective visual assessment was also efficient in increasing PPV, it occasionally missed malignant uptake.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call