Abstract

<strong class="journal-contentHeaderColor">Abstract.</strong> We describe an approach for determining limited information about the vertical distribution of carbon monoxide (CO) and carbon dioxide (CO<sub>2</sub>) from total column observations from ground-based TCCON observations. For long-lived trace gases, such as CO and CO<sub>2</sub>, it has been difficult to retrieve information about their vertical distribution from spectral line shapes in the shortwave infrared (SWIR) spectra because of the large doppler widths at 6000 cm<sup>-1</sup>, and errors in the spectroscopy and in the atmospheric temperature profile which mask the effects of variations in their mixing ratio with altitude in the troposphere. For CO<sub>2 </sub>the challenge is especially difficult given that these variations are typically 2&thinsp;% or less. Nevertheless, if sufficient accuracy can be obtained, such information would be highly valuable for evaluation of retrievals from satellites and more generally for improving the estimate of surface sources and sinks of these trace gases. We present here the Temporal Atmospheric Retrieval Determining Information from Secondary Scaling (TARDISS) retrieval algorithm. TARDISS uses several simultaneously obtained total column observations of the same gas from different absorption bands with distinctly different vertical averaging kernels. Since TARDISS avoids spectral re-fitting by ingesting retrieved column abundances, it is very fast and processes years of data in minutes. The different total column retrievals are combined using a Bayesian approach where the weights and temporal covariance applied to the different retrievals include additional constraints on the diurnal variation in the vertical distribution for these gases. We assume that only the near surface is influenced by local sources and sinks, while variations in the distribution in the middle and upper troposphere result primarily from advection that can be independently constrained using reanalysis data about the variation in mid-tropospheric potential temperature. Using measurements from five North American TCCON sites, we find that the retrieved lower partial column (between the surface and ~800 hPa) of the CO and CO<sub>2</sub> dry mole fractions (DMF) have slopes of 1.001&plusmn;0.002 and 1.007&plusmn;0.002 with respect to lower column DMF from integrated in situ data measured by aircraft and AirCore. The average error for our CO retrieval is 0.857 ppb (~1&thinsp;%) while the average error for our CO<sub>2</sub> retrieval is 3.55 ppm (~0.8&thinsp;%). We calculate degrees of freedom from signal of 0.218 per measurement for lower partial column CO on average and of 0.353 per measurement for lower partial column CO<sub>2</sub> on average. Compared with classical line-shape-derived vertical profile retrievals, our algorithm reduces the influence of forward model errors such as imprecision in spectroscopy (line shapes and intensities) and in the instrument line shape. We anticipate that this approach will find broad application for use in carbon cycle science.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.