Abstract
<strong class="journal-contentHeaderColor">Abstract.</strong> Model Output Statistics (MOS) approaches relying on machine learning algorithms were applied to downscale regional air quality forecasts produced by CAMS (Copernicus Atmosphere Monitoring Service) at hundreds of monitoring sites across Europe. Besides the CAMS forecast, the predictors in the MOS typically include meteorological variables but also ancillary data. We explored first a “local” approach where specific models are trained at each site. An alternative “global” approach where a single model is trained with data from the whole geographical domain was also investigated. In both cases, local predictors are used for a given station in predictive mode. Because of its global nature, the latter approach can capture a variety of meteorological situation within a very short training period and is thereby more suited to cope with operational constraints in relation with the training of the MOS (frequent upgrades of the modelling system, addition of new monitoring sites). Both approaches have been implemented using a variety of machine learning algorithms: random forest, gradient boosting, standard and regularized multi-linear models. The quality of the MOS predictions is evaluated in this work for four key pollutants, namely particulate matter PM<sub>10</sub> and PM<sub>2.5</sub>, ozone O<sub>3</sub> and nitrogen dioxide NO<sub>2</sub>, according to scores based on the predictive errors and on the detection of pollution peaks (exceedances of the regulatory thresholds). Both the local and the global approaches significantly improve the performances of the raw Ensemble forecast. The most important result of this study is that the global approach competes with and can even outperform the local approach in some cases. This global approach gives the best RMSE scores when relying on a random forest model, for the prediction of daily mean, daily max and hourly concentrations. By contrast, it is the gradient boosting model which is better suited for the detection of exceedances of the European Union regulated threshold values for O<sub>3</sub> and PM<sub>10.</sub>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.