Abstract

ABSTRACT There exists a significant risk of water blooms during the utilization of recycled water in landscape environments. The nitrogen and phosphorus discharge standards of sewage treatment plants are very low. Controlling hydraulic retention time (HRT) is currently the most effective means to control water bloom. This article proposes a new method for determining the HRT threshold based on water transparency as a control indicator. The following results were obtained: (1) with the nitrogen and phosphorus concentrations of 15 and 0.5 mg/L, respectively, the threshold for HRT under high temperature and strong light is 4.6 days, while the threshold under low temperature and low light is 11.5 days. (2) With the nitrogen and phosphorus concentrations of 10 and 0.3 mg/L, respectively, the threshold for HRT under high temperature and strong light is 5 days, while the threshold under low temperature and low light conditions is 12.3 days. (3) The HRT threshold obtained under high temperature and strong light is lower than that obtained under low temperature and low light conditions. (4) The higher the concentrations of nitrogen and phosphorus, the smaller the HRT threshold obtained. (5) Blue algae have stronger adaptability than green algae and diatoms.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call