Abstract

Enhanced pause (Penh) was first proposed in allergic mice and appeared to be correlated with airway responsiveness. However, some investigators have suggested that there is no theoretical basis for a correlation between Penh and airway resistance. Because the measurement of Penh is a noninvasive procedure, this value may be useful in repetitive measurements, but few researchers have emphasized this aspect. This study aimed to assess the validity of Penh values derived through repetitive measurements of both absolute and ratio Penh values in 10 male C57BL/6 mice on days 0, 3, 7, and 15. Tests of within-subject effects revealed significant differences in both the absolute and ratio Penh values across the different time points. The administration of challenge aerosolized methacholine concentrations of 25, 50, and 100mg/ml resulted in significant differences in the ratio Penh values across the various time points. The findings of the present study indicate that Penh is not a good index for repetitive measurement because the Penh values are significantly influenced by the time at which they are measured.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.