Abstract

The development of a field-amplified sample stacking technique is presented. Sensitivity enhancement in this technique was obtained by repetitive injections of a sample followed by steps of sample matrix removal through the application of counter-pressure. Under optimized conditions the background electrolyte (BGE) was composed of 80mM H3PO4 while the sample matrix contained 0.5mM H3PO4 and 30% (v/v) methanol. The elaborated method enabled a 4-fold effective injection of the sample (53s, 0.5psi). Each injection was followed by a focusing step during which the application of a voltage (2kV) and counter-pressure (−1psi) was performed for 0.65min. The method was developed for the determination of six psychiatric drugs (opipramol, hydroxyzine, promazine, amitriptyline, fluoxetine, and thioridazine). The elaborated method was applied for analysis of human urine samples after a simple liquid–liquid extraction procedure. The detection limits obtained were in the range of 2.23–6.21ng/mL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.