Abstract

Statement of problemAlthough different digital occlusal analyzers have been marketed, comparative studies are lacking. PurposeThe purpose of this in vitro study was to compare the repeatability and reproducibility of 2 different digital occlusal analyzers (T-Scan and OccluSense) for measuring the right- and left-side balance of occlusal contact forces. Material and methodsThe repeatability and reproducibility of the 2 digital occlusal analyzers for measuring the balance of occlusal contact forces were determined and compared by using the Gauge Repeatability and Reproducibility tests based on the International Organization for Standardization (ISO), ISO 5725-2 and ISO 5725-3 standards. Ten different dental casts were mounted in the maximum intercuspation position on a semi-adjustable articulator. Then, the balance of occlusal contact forces in each of the 10 articulated dental casts was measured 24 times with each of the 2 digital occlusal analyzers. In addition, as the OccluSense, unlike the T-Scan, does not have a centering support for the piezoelectric film sensor, measurements with it were performed without and with a custom-designed and manufactured centering support. Finally, the repeatability and reproducibility of both digital occlusal analyzers were determined and compared using the Gauge Repeatability and Reproducibility tests. ResultsThe repeatability and reproducibility tests revealed that only 0.8% of the variance of the measurements obtained with the T-Scan was due to repeatability and reproducibility (0.4% repeatability, 0.4% reproducibility). In contrast, 12% of the variance of the measurements obtained with the OccluSense was due to repeatability and reproducibility (2.2% repeatability, 9.8% reproducibility). However, when using OccluSense with the centering support, the variance decreased to 6.4% (2.8% repeatability, 3.6% reproducibility). According to the Automotive Industry Action Group classification, the repeatability and reproducibility of the T-Scan were good, those of the OccluSense poor, and those of the OccluSense with the centering support medium. ConclusionsThe repeatability and reproducibility of the T-Scan were significantly better than those of the OccluSense for measuring the balance of occlusal contact forces. Furthermore, the repeatability and reproducibility of the OccluSense were significantly improved when used with a device to center the piezoelectric film sensor between the incisors. Nevertheless, the repeatability and reproducibility of the T-Scan were better.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call